WHISPERKOOL SERIES ADVANCED CONTROLLER CONT.
Set
1. Press the “Set button once and it will display the set point. After about 5 seconds, the display
will return to normal operation and display the bottle probe temperature.
2. Press and hold the “Set” button for 3 to 5 seconds until the set point is displayed and the °F
symbol starts blinking. Then, press the “Up” or “Down arrow to change the set point. Next,
press the “Set” button once and the set point numbers and the temperature on the display will
blink to conrm the new set point.
3. Press the “Up button to display the high temperature data history, or press the “Down button
to see the low temperature history. Once the high/low data history is displayed, it can be reset
by holding the set button (“RST will blink on the display). It will then erase the past recorded
data le and start recording from the current time and temperature.
4. Press the “Set and the “Down buttons simultaneously for 3 to 5 seconds and you will
access the customer preference selection menu. The menu allows the customer to tweak the
control system to their applicable choice.
Customer
Preference
Selection
Menu
(CPSM)
To access the CPSM, press the Set and Down buttons simultaneously for 5-7 seconds. This will
display “CF”, now press the Set and Down buttons simultaneously for another 5-7 seconds. The
display will briey show “Pr2” signifying you have accessed the CPSM.
The following CPSM options are available for adjustment:
Fon Humidity management: This parameter is normally set at 5, which should provide ad-
equate relative humidity for the cellar.
o An increase in this parameter will increase the humidity (%RH), and a decrease in the pa-
rameter will decrease humidity.
o Adjustments should be made in increments of 5, with a maximum of 15, and a
minimum of 0.
oAfter any adjustment to Humidity Enhancement, you should wait a minimum of three days
before making any additional adjustments. This will allow the cellar sucient time to accli-
mate to the new setting.
Fof Humidity Management Enhancement: This parameter is normally set at 5. This
parameter usually should not be adjusted, as it provides an o cycle time for the fan during the
compressor o cycle.
CCS — Cellar Pre-Chill Set Point: This parameter is set at 52°F, but can be adjusted to a set point
between 45°F and 67°F.
bLL/Act Compressor o or on for low (bLL) or high (Act) temperature alarm: These
parameters are set at “n. With this parameter set at “n, the refrigeration system will continue to
operate normally if there is a high or low temperature alarm. To change this parameter, change
the setting to “y, and the compressor/refrigeration system will shut o during a high or low tem-
perature alarm.